Description

When launching Source-Connect Standard 3.9, the application immediately tries to login but does not show a username or password. The application becomes unresponsive and will never login. If the application is force quit and launched again, the same behavior occurs. Reinstalling will allow Source-Connect to launch properly again.

Cause

This is a known bug in Source-Connect Standard 3.9 that can occur if a high-numbered channel is selected for either the audio input or output device. For example, if you have a 24 channel audio device, and then select channel 20 in the audio options, everything will work properly until Source-Connect is quit and relaunched and then the issue occurs. This is because of a bug in the way that Source-Connect saves the audio device preference. When a high numbered channel is selected, Source-Connect may save it as the wrong number which may be higher than the actual amount of channels the device has. Then when Source-Connect is launched, and attempts to load the preferences, it cannot because the channel it tries to load does not exist.

Actions

  • Disconnect all audio devices from the computer and then try launching Source-Connect.
  • Reinstall Source-Connect. This will clear the saved preferences and allow it to launch properly again.
  • If using a high numbered channel from an audio device, change it back to channel 1 before quitting Source-Connect.
  • Use Source-Nexus I/O or Source-Connect Link in a DAW to use a high numbered channel from an audio device.

Was this article helpful?

Yes
No
Give feedback about this article

Table of Contents

Description Cause Actions

PRODUCTS

  • Source-Connect™ 4 Hub
  • Source-Connect™ 4 Talent
  • Source-Connect™ 4 Studio/Facility
  • Source-Connect™ Standard 3.9
  • Source-Connect™ Pro & Pro X 3.9
  • Source-Live™ Pro LL
  • Source-Nexus™ Suite
  • Source-Nexus™ Control Panel
  • Source-Nexus™ Gateway
  • Source-Nexus™ I/O
  • Source-Nexus™ Mute-On
  • Source-Nexus™ Review
  • Source-Nexus™ Router
  • Source-Stream™

ACADEMY

  • Source-Connect 4 Talent Course
  • Advanced Remote Recording for VO Artists
  • Source-Connect 4 Studio/Facility Course
  • Source-Nexus I/O 1.3 Free Introductory
    Course

ILOK AND LICENSES

  • iLok Documentation
  • Licensing Documentation

POLICIES

  • Network Access and Support Contract Policies
  • Technical Support Terms and Conditions
  • Technical Support Disclaimer
  • Source Elements Terms and Conditions
  • Source Elements Privacy Policy
  • Source Elements Purchase Policy
  • Source Elements Refunds Policy
  • Source Elements Cookies Policy

GET LIVE SUPPORT

  • Purchase Support
  • Book a session
  • Contact us for support

ABOUT US

  • Meet the team!

Copyright © 2025. Source Elements. All rights reserved.


Expand

  • Error Message Repository

Was this article helpful?

Yes
No
Give feedback about this article